Smallest Round Shape RFID EM ID Reader 125Khz Wiegand 26 Output Red LED
Z2L RFID Reader
 EM Marine
 iButton (Dallas TM), Wiegand 26
 12 V
 35 miliamper
 TU 4372-002-38111914-2015
 GENERAL INFORMATION
 Controller is used in access control systems (ACS).
 It is used to read and transfer ID numbers to the
 controller
 key fobs or bracelet with mark
 standard
 EM-marine
 via protocol
 Dallas Touch Memory (Ibutton) или Wiegand 26.
 APPEARANCE AND DIMENSIONS
 READER OPERATION
 In standby mode, there is a red light.
 At the moment of touch by key fob, the red light will turn off for one second.
 While the card close to the reader, the light indication is disabled.
 If the jumper of light control is cut, there is no red light in standby mode, but there will be
 the light for one second at the moment of touching by key fob.
 PURPOSE OF PINS
 Color - Purpose of wire
 Red - Power Plus from 8 to 18 V.
 Black - power minus, common wire.
 Blue - Data 0
 White - Data 1 / Output Dallas TM, TM centeral.
 Brown - a jumper, to disable the backlight cut.
 WIRING
 DELIVERY SET
 Reader - 1.
 Nut - 1 pc
 Packaging - 1 pc.
 READER INSTALLATION
 The reader is mounted on a flat surface in place where you can touch the key fob to
 reader without any problems
 Mark and drill the hole for mounting the reader.
 Insert the reader into the hole and secure it with mounting nut
 Connect the wires to the reader.
 1 - red LED
 2 - retention ring
 SPECIFICATIONS
 Operating frequency: 125 kHz
 Type readable cards: EM Marine
 Range of card reading to 2-6 cm
 Protocol for connection to the controller: iButton (Dallas Touch Memory, emulation
 DS1990A), Wiegand 26
 Maximum length of line from reader to controller: up to 15m
 Power supply: 8 - 18 VDC
 Current consumption: 35 mA
 Light indication: Red LED
 Housing material: Polyamide
 Size (mm): Diameter 25 mm., Height 22 mm.
 OPERATING CONDITIONS STORAGE AND TRANSPORT
 Converter is designed to operate in the absence of:
 Atmospheric fallouts, sunshine and humidity condensation.
 Operating conditions
 Temperature from -30 ° C to +40 ° C;
 Relative humidity less than 98% (at 25 ° C).
 When there are changes in maintenance conditions, the specification of product may
 differ from the nominal values.
 Storage conditions (group L according to GOST 15150-69)
 Temperature from +5 ° C to +40 ° C;
 Relative humidity less than 80% (at 25 ° C).
 Transportation conditions:
 Temperature from -50° C to +50 ° C;
 Relative humidity less than 98% (at 25 ° C).
 WARRANTY
 The warranty period is 24 months from the date of sale. Reasons for termination of the
 warranty:
 - nonadherence to the following manual;
 - mechanical damages;
 - the evidence of impact of water and corrosive substances;
 - the evidence of improper interference in the circuit.
 - Lifetime - 6 years.